illuminating technologies for life
Home
Information Specifications Manuals
Warranty Literature Parts
Information Specifications Manuals Warranty Literature Parts
Residential LUMINOR EQUIPMENT SPECIFICATIONS
BLACKCOMB5.0, Residential UV systems, modular non-monitored
MODEL LB5-031 LB5-061 LB5-101 LB5-151 LB5-201
Flow Rate
(@ 16 mJ/cm²)
6.1 gpm 11 gpm 20 gpm 30 gpm 39 gpm
23 lpm 41 lpm 77 lpm 110 lpm 150 lpm
1.4 m³/hr 2.5 m³/hr 4.6 m³/hr 6.8 m³/hr 8.9 m³/hr
Flow Rate
(@ 30 mJ/cm²)
3.1 gpm 5.8 gpm 11 gpm 15 gpm 21 gpm
11 lpm 23 lpm 41 lpm 57 lpm 79 lpm
0.7 m³/hr 1.3 m³/hr 2.5 m³/hr 3.4 m³/hr 4.8 m³/hr
Flow Rate
(@ 40 mJ/cm²)
2.4 gpm 4.4 gpm 8.3 gpm 12 gpm 16 gpm
9.1 lpm 17 lpm 31 lpm 45 lpm 59 lpm
0.5 m³/hr 1.0 m³/hr 1.9 m³/hr 2.7 m³/hr 3.6 m³/hr
Port Size ½" MNPT ¾" MNPT ¾" MNPT 1" MNPT 1" MNPT
Electrical 90-265V / 50-60Hz
Plug Type American: Nema 5/15 - "1" suffix (i.e. LB5-101)
European: CEE 7/7 - "2" suffix (i.e. LB5-102)
British Standard: BS 1363 - "3" suffix (i.e. LB5-103)
Australian/New Zealand: AS/NZ 3112 - "4" suffix (i.e. LB5-104)
Lamp Watts 15 22 39 50 42
Power (watts) 20 30 49 62 51
Chamber Material 304 Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated
Replacement Lamp RL-290 RL-470 RL-820 RL-999 RL-850
Replacement Sleeve RQ-290 RQ-470 RQ-820 RQ-999 RQ-850
Reactor Dimensions 2.5 x 14.3"
(6.4 x 36.3 cm)
2.5 x 21.3"
(6.4 x 54.1 cm)
2.5 x 35.2"
(6.4 x 89.4 cm)
2.5 x 40.0"
(6.4 x 101.6 cm)
3.5 x 36.1"
(8.9 x 91.7 cm)
Controller Dimensions 6.8 x 3.6 x 3" (171.5 x 92.1 x 76.2 mm)
Maximum Operating Pressure 10 bar (150 psi)
Operating Temperature Range 2-40° C (36-104° F)
UV Monitor No Optional
Solenoid Output Optional
4-20 mA Output Optional
Lamp Change Reminder (audible & visual) Yes
Lamp-Out Indicator (audible & visual) Yes
Shipping Weight 3.6 kg (8.0 lbs) 4.2 kg (9.2 lbs) 6.8 kg (15.0 lbs) 8.0 kg (17.6 lbs) 7.4 kg (16.4 lbs)