illuminating technologies for life
Home
Information Specifications Manuals
Warranty Literature Parts
Information Specifications Manuals Warranty Literature Parts
Icon LUMINOR EQUIPMENT SPECIFICATIONS
K2 Industrial / Commercial UV Systems, UV monitored
MODEL LK6-A12 LK6-A22 LK6-A42 LK6-A62
Flow Rate*
(@ 16 mJ/cm²)
167 gpm 327 gpm 758 gpm 1170 gpm
630 lpm 1240 lpm 2870 lpm 4420 lpm
37.8 m³/hr 74.3 m³/hr 172 m³/hr 265 m³/hr
Flow Rate
(@ 30 mJ/cm²)
88.8 gpm 174 gpm 404 gpm 623 gpm
336 lpm 659 lpm 1530 lpm 2360 lpm
20.2 m³/hr 39.5 m³/hr 91.8 m³/hr 141 m³/hr
Flow Rate
(@ 40 mJ/cm²)
66.6 gpm 131 gpm 303 gpm 467 gpm
252 lpm 496 lpm 1150 lpm 1770 lpm
15.1 m³/hr 29.8 m³/hr 68.8 m³/hr 106 m³/hr
Port Size 2" MNPT 3" Flange 4" Flange 6" Flange
Electrical 220V/50-60Hz direct wire
Lamp Watts 207 414 828 1242
Power (watts) 240 460 900 1340
Chamber Material 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated
Replacement Lamp RL-1000A
(1 required)
RL-1000A
(2 required)
RL-1000A
(4 required)
RL-1000A
(6 required)
Replacement Sleeve RQ-K2
(1 required)
RQ-K2
(2 required)
RQ-K2
(4 required)
RQ-K2
(6 required)
Reactor Dimensions Contact factory for further information
Controller Dimensions Contact factory for further information
Controller Enclosure Modified NEMA 4X
304 Stainless Steel
Maximum Operating Pressure 10 bar (150 psi)
Operating Temperature Range 2-40° C (36-104° F)
254nm UV Intensity Monitor Yes
UVT Monitoring Optional
Dose Calculations Optional
Flow Monitoring Optional
Internal Falt History Yes
Remote-On Yes
Dry Contacts (Solenoid-ready) Yes
4-20 mA Output Yes
Drain Ports 3/8" ½"
Lamp Age Counter Yes
Sample ports No Yes
Visual Lamp-Out Indicator Yes
Audible Lamp-Out Alarm Yes
Shipping Weight Contact factory for further information