LUMINOR EQUIPMENT SPECIFICATIONS
RAINIER5.0, Light Commercial Amalgam UV Systems, non-monitored
MODEL LR5-355 LR5-555 LR5-855 LR5-1105 LR5-1405 LR5-1755
Flow Rate
30 mJ/cm² @ 95%
UVT (Industry Std.)
35 gpm 58 gpm 85 gpm 110 gpm 140 gpm 175 gpm
132 lpm 220 lpm 322 lpm 416 lpm 530 lpm 662 lpm
8.0 m³/hr 13.2 m³/hr 19.3 m³/hr 25.0 m³/hr 31.8 m³/hr 39.7 m³/hr
Alternate Flow Rate
16 mJ/cm² @ 95% UVT (US Public Health)*
66 gpm 109 gpm 167 gpm 207 gpm 263 gpm 327 gpm
250 lpm 413 lpm 632 lpm 784 lpm 996 lpm 1240 lpm
15.0 m³/hr 24.8 m³/hr 37.9 m³/hr 47.0 m³/hr 59.7 m³/hr 74.3 m³/hr
Alternate Flow Rate
40 mJ/cm² @ 95% UVT
27 gpm 44 gpm 67 gpm 84 gpm 106 gpm 131 gpm
102 lpm 167 lpm 252 lpm 318 lpm 401 lpm 496 lpm
6.1 m³/hr 10.0 m³/hr 15.1 m³/hr 19.1 m³/hr 24.1 m³/hr 29.8 m³/hr
Port Size 1½" 2" 2" 2½" 3" 4"
Electrical 230V / 50-60Hz
(IEC power cords required)
Plug Type North American NEMA 6/15: "5" suffix
European CEE 7/7: "2" suffix
British BS1363: "3" suffix"
Australian AS/NZ 3112: "4" suffix
Lamp Watts 104 152 207 304 344 414
Power (watts) 120 170 220 320 360 430
Replacement Lamp RL-500A RL-720A RL-1000A RL-720A
(2 required)
RL-843A
(2 required)
RL-1000A
(2 required)
Replacement Sleeve RQ-500 RQ-720 RQ-1000 RQ-720
(2 required)
RQ-843
(2 required)
RQ-1000
(2 required)
Chamber Material 316L Stainless Steel, A249 Pressure Rated Tubing, Polished & Passivated
Reactor Dimensions 4x27.2x5.6"
10x69x14cm
4x35.8x5.6"
10x91x14cm
4x46.8x5.6"
10x119x14cm
6x35.8x7.9"
15x91x20cm
6x40.6x7.9"
15x103x20cm
6x46.8x7.9"
15x119x20cm
Controller Dimensions 11.8 x 7.9 x 6.3" (30.0 x 20.1 x 16.0 cm)
Maximum Operating Pressure 10.3 bar (150 psi)
Operating Temperature Range 2-40° C (36-104° F)
UV Monitor Upgradeable, includes visual glow plug
Remote-On Yes
Dry Contacts (solenoid ready) Optional
4-20 mA Output Optional
Lamp Age Counter Yes
Lamp-Out Indicator (audible & visual) Yes
*Note: based on flow velocity of 8.2 ft/s (2.5 m/s), flow rates are limited by port sizes:
1½": 52gpm (197 lpm)
2": 85.8gpm (325 lpm)
2½": 122.4 gpm (463 lpm)
3": 189 gpm (715 lpm)
4": 325.4 gpm (1232 lpm)